Viracon glass calculator pdf Altering the thickness of an interlayer in a laminated glass unit, will have an insignificant effect on performance data. See the following for further information: Deflection and Sightline Reference Guide. Viracon high-performance coatings can be combined with the print offering to achieve optimum solar performance and aesthetics. In circumstances where a coating or film has been applied to a Viracon glass unit that subsequently warrants replacement under Viracon’s Viracon Revit Files. 2080. The glass unit size, ply thicknesses and heat treatment impact the strength and center of glass deflection. The surface in contact with the tin is known as the tin surface or tin side. BIG Glass creates additional factors that should be considered. com 2. If additional edgework is required, contact a Viracon representative for pricing. Viracon's products will be fabricated with Type I─Transparent Flat Glass, Class 1─Clear or Class 2─Tinted, Quality-Q3. The thicker the glass the more durable it is adding to the structural stability of the window. To get started, input your required performance data below. As the u-value decreases, so does the amount of heat that is transferred through the glazing material. The solar performance of a glass unit results from the configuration of the unit along with the thickness of the glass used. sets, airport control towers to woolly . Viracon is a leading single-source architectural glass fabricator. 2 / 120. Viracon is an architectural glass fabricator, our track record includes four decades of service, 100,000 buildings, and 500,000,000 square feet of glazing installed in some of the most remarkable buildings throughout the world. 1 and CPSC 16 CFR 1201, which are the industry safety standards for glazing materials. AGC Glass Configurator Single & Laminated Glass Data. Viracon Glass /Viridian Glass/Vitro Glass (formerly PPG Glass) Availability: Metric Unit & Imperial Unit, ASHARE standard & EN standard. - All May 6, 2020 · A measure of heat gain or heat loss through glass due to the thermal conductance and the difference in indoor and outdoor temperatures. Our passion for glass and design is With Viracon PLUS™ Smart Glass buildings are more energy efficient and healthier for occupants and the environment. next big challenge. to purchase uncoated raw glass from the float glass manufacturer. com or By Calling 800. Gracing the world’s skylines Selling glass solutions, says Viracon, is its business. 24psf The freight calculation above applies for units <= 110" in both dimensions. Each interlayer has different availability with each of Viracon’s coatings. 25psf Production Ready Purchase Order Date: July-24 Viracon Index on that Date: 120. The minimum glass thickness is represented by the diagonal line directly above this intersection, providing you with the minimum recommended laminated glass makeup of two plies of 1/2” May 6, 2020 · Building Glass with Ceramic Frit is also used to create Bird-Friendly Glass facades. Explore Viracon's extensive product range with our easy-to-use product search tool. Type glass thickness-Calculate-Download performance datasheet in PDF file. He is a LEED Green Associate and has worked in the construction industry for 15 years. Title: Microsoft Word - 2. Viracon can provide offset insulating units with 1, 2 or 3 edges offset. 5 software, NFRC 100 – 2010 conditions have been used. This manual, along with Viracon’s Purchase Orders, General Terms and Conditions, drawings, specifications and any applicable warranties or other documentation approved glass fabricators, Viratec and Tru Vue , are also a part. Laminated products: The Performance Calculator allows the user to model a wide variety of laminated glass makeups using different float glass substrates, coatings and interlayer material, including those makeups where the coating faces the interlayer. The Performance Calculator allows the user to model a wide variety of laminated glass makeups using different float glass substrates, coatings and interlayer material, including those makeups where the coating faces the interlayer. always leave us in anticipation of the . 2-625 Viracon’s General Information 07/07/22) P ricing Information (All pricing in US Dollars) Viracon seams all heat treated glass edges. Please note: Viracon’s Revit files provide a representation of actual Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. 25 or greater to be Green Glazing/Spectrally Selective Glazing. The thickness of the spacer will determine the distance, or space, between the two glass plies in an insulating unit. Viracon offers printed patterns on glass with either ceramic enamel paints or digital inks. The Performance Calculator allows the user to model a wide variety of laminated glass makeups using different float glass substrates, coatings and interlayer material, including those makeups where the coating faces the interlayer. Tests have shown that when windows glazed with laminated glass are subjected to a blast impulse, broken glass fragments tend to adhere to the plastic interlayer rather than To learn more about Viracon glass coatings, visit www. viracon. 030″ (0. Tests have shown that when windows glazed with laminated glass are subjected to a blast impulse, broken glass fragments tend to adhere to the plastic interlayer rather than May 6, 2020 · As a result it is not recommended for glass selection of exterior wall applications since the single-number rating was achieved under a specific set of laboratory conditions. 7 = $1. Supplier Quality Assurance Manual (PDF) - based on Viracon’s quality system requirements and is considered to be included as part of Viracon’s requirements for suppliers. CyberShield; DigitalDistinctions; Glass Is Everything; RoomSide; StormGuard; The Leader in Architectural Glass Fabrication; Viracon; VTS; The terms and brands listed January 2020 Vitro® Architectural Glass (PPG) AGC Glass Guardian® Glass Cardinal® Glass Viracon® Saint‐Gobain NSG (Pilkington) Sungate® 400 ENERGY Select® 73 Plus SunGuard® Neutral 78/65 LoE‐180™ VE1‐85 Planitherm HNII Energy Advantage™ strengthened glass to have a surface compression between 3,500 and 7,500 psi (24 to 52 MPa). 533. That’s nothing new at Viracon-it’s been our focus for over 45 years. Welcome to our interactive glass selector tool where you can find glass that meets your performance requirements. Viracon recommends tempered glass for safety glazing applications only. Nov 2, 2023 · Viracon’s General Information Page 1 of 3 Pricing Information (All pricing in US Dollars) • Viracon seams all heat treated glass edges. Shown here are a few examples: For cooling dominated buildings, the best solar performance is achieved when the coating is applied to the #2 surface, therefore Viracon coatings are located on the #2 surface. From Manhattan penthouses to Hollywood movie . 2080 viracon. 02. Moiré Pattern Moiré is an optical phenomenon that typically appears as a wavy, rippled or circular pattern. Options are provided for annealed, toughened and laminate panes of standard nominal thicknesses. If you’re undecided on the glass selection you would like to use for your project we’d be happy to discuss all your options and send you samples. Viracon is excited to be joining @facadesplus on May 12nd, 2023 for expert dialogues on facades. Additional information about the research and testing is available in the Tech Talk. The design professional must confirm applicable code and design. Architectural Glass Solutions for Your Next Landmark Project Start By Visiting viracon. DigitalDistinctions® is the digital ink printed solution, while silkscreen prints utilize ceramic enamel paints. May 6, 2020 · Two or more pieces of glass bonded together by a piece of plastic/vinyl called polyvinyl butyral (PVB). We will respond within 48-72 hours with the glass type, the full glass composition and the finished size. Glass size and glazing system will affect STC rating. March. Today, Viracon is the largest business in the Glass Technologies segment with approximately 1,200 people in its employ. It looks like typical facade glass, but offers the unique ability to control the tint to reduce solar heat gain and glare. 2 Freight Charged: $1. 2024 Prepared for Performance By Seier, Gordon gordon@agm-inc. There are both ASTM and European Standards commonly utilized to calculate glass strength. Viracon makes high-performance glass products including Insulating Glass Construction STC OITC* 100 125 160 200 250 315 400 500 630 Viracon Acoustical Glass is made from combinations of various glass types along with Apr 2, 2023 · Raw glass purchased by Viracon for our glass products meets the requirements of ASTM C1036 Standard Specification for Flat Glass. 03 LAMINA TED ACOUSTI CAL DATA Frequency (Hz) Laminated Glass Construction STC OITC* 100 125 160 200 250 315 Viracon has a vast selection of coatings, glass substrates and other components. 2mm) nominal thickness spacer; however, a wide variety of alternate thickness spacers are available. Saint Gobain Glass (SGG) Tecnoglass. Viracon does not fabricate staggered insulating units where both glass plies are the same size and assembled so they are offset from one another. com. Vitro Architectural Glass | 400 Guys Run Road Cheswick, PA 15024 USA | ©2001-2025 Vitro Flat Glass llc. See additional notes below data for specific A leader in tools for the glass industry. Viracon is an architectural glass fabricator , our track record includes four decades of service, 100,000 buildings, and 500,000,000 square feet of glazing installed in some of the most remarkable buildings throughout the world. fabrication shop providing glass to a variety of . For assistance with a quote, order status or to find your local representative, select your location below. com 2044515458 Guardian-Vitro-Cardinal ++ dual Make-up Name Glass 1 & Coatin g Glass The performance data below applies to an insulating unit constructed with two plies of glass and an air or argon filled space. An integrated, user-friendly, and widely-acknowledged tool accepted by architects, designers, builders, glass manufacturers, glass experts, glass processors, homeowners. Built around safety and professionalism, Viracon rewards and recognizes both individual and team accomplishments and contributions. Financing / Credit Application. Viracon PLUS™ Smart Glass powered by HALIO® is the most advanced tinting glass available. When you need to know the glass makeup, locate the VIN found on the unit’s VTS profile, enter it below, answer the questions and then submit the information. The English System relative heat gain is calculated as: RHG = (Summer U-value x 14°F) + (Shading Coefficient x 200). com Page 1 of 1 VIRACON’S STANDARD FIVE-YEAR LIMITED GLASS CLAD POLYCARBONATE WARRANTY ADVANCED SMART GLASS TINTS AND CLEARS ON DEMAND GREAT BUILDINGS DESERVE GREAT GLASSTM Viracon PLUS Smart Glass powered by Halio is a remarkable leap forward in architectural glass technology, enabling glass to tint automatically or on demand with significantly improved aesthetics and transition speeds compared to legacy tinting Green building design is a major influence. The STC rating Existing Item on Color Calculator. The values given are centre of glass values. The conference encompasses all things building skin—bridging the profession, industry, academia. Glass facades deliver many benefits including daylight, views and dynamic aesthetics. 25psf * 120. Glass weight estimator tool. Viracon does not assume responsibility for problems created by, or associated with, applied coatings or films, including breakage or incompatibility between the glass unit and the coating or film. To learn more about BIG Glass by Viracon, visit BIG Glass. The improved aesthetic, durability and sound-dampening of thicker glass deliver the exceptional quality your project requires for long-term value. Single Component Thermo Spacer. We celebrate employee milestones, exceptional performance, and team safety goals. Fortunately, there are some tools we can use when we choosing the suitable glass types we need. He can be reached via email at bsavage@viracon. Interlayers and Coatings. Glass Analytics online tools offer a comprehensive suite of engineering and analytical reports that demonstrate the advantages of high-performance glass in building facades. Save as PDF 800 Park Drive , Owatonna , MN 55060 US | (800) 533-2080 whereas, Low-E coatings on tinted glass have a solar absorption between 55 and 80 percent. com/projects/view/id/12/ https://www. We partner with best-in-class architecture firms and glazing contractors to provide great buildings with great glass - glass that inspires and turns buildings into icons. 3-9981-MGU 11/03/2017 Page 1 of 1 The Impact of Ceramic Frit on Glass Strength Ceramic frit applied to a glass surface, also referred to as enameled glass, has been shown to reduce glass strength when compared to non-enameled glass. Tinted and/or coated glass that reduces the amount of solar heat gain transmitted through a glazing product. Read more about the tools below National Glass Association 344 Maple Ave West Unit 272 Vienna, VA 22180 703/442-4890. 76mm) meets the requirements of ANSI Z97. Deflection and Sightline Reference Guide – Document to assist you with the process of selecting glass to withstand loads, minimize center of glass deflection and identify the appropriate sightline. Contact us. com/projects/view/id/13/ https://www. To learn more, CALL 800-533-2080 Now! '(7(&7,21 6wdjhv ri *odvv 6wdlqlqj 'xulqj wkh iluvw vwdjh ri vwdlqlqj \rx zloo vhh d wudqvsduhqw zklwh ilop dsshdu rq wkh jodvv 8qghu fhuwdlq oljkwlqj frqglwlrqv iru lqvwdoohg jodvv wkdw kdv qrw ehhq zdvkhg wkh zklwh ilop fryhuv wkh hqwluh Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. Simplify your glass selection process with Viracon’s advanced tools and expertise. Viracon executes the fabrication processes as specified by customer orders: cutting the glass to the custom sizes, applying print then heat treating the glass prior to applying a high performance coating. It is the user’s responsibility to Glass size and glazing system will a˜ect STC rating. For the offset, the exterior ply must be larger than the interior ply. Superior aesthetics - the coating is applied after heat treating, augmenting flatness compared to architectural glass that is heat treated after the coating application. Viracon recommends a 5-7° lean against two wide, sturdy uprights, which are capable of withstanding crate weight. Viracon’s typical 1” insulating units are constructed using a 1/2” (13. The library contains 55 products in a zip folder giving you access to all 55 products with one simple download. Find the perfect glass solutions for your projects today. Financing / Credit Ap – Use this form to receive Viracon’s credit application. Laminated glass offers protection when a building is exposed to the threat of explosives. Quick Links to Architectural Glass Projects by Viracon. Insulating glass units produced by Viracon with a pressure-compensated spacer must deliver to project elevation within 12 months. The Department of Energy’s Federal Technology Alert publication of the Federal Energy Management Program (FEMP) views an LSG of 1. Viracon PLUS Smart Glass powered by Halio is a remarkable leap forward in architectural glass technology, enabling glass to tint automatically or viracon. It is the user’s responsibility to May 14, 2021 · It is hard for us to know how much DB noise has been blocked during transmission. This user-friendly platform lets you compare options, review specifications, and make informed decisions with ease. • Order changes following Viracon’s receipt of a signed order confirmation may be subject to a $500 order May 2, 2020 · A laminated glazing construction commonly specified to mitigate injuries from flying glass resulting from an air-blast explosive. Page 1 of 5 PERFORMANCE CALCULATOR 26. Argon Fill Standard Secondary Sealant. Savage has helped launch numerous new glass-related products at Viracon. viracon. Jul 7, 2022 · Viracon’s General Information (Updated 2. Save as PDF 800 Park Drive , Owatonna , MN 55060 US | (800) 533-2080 As a result, it is important that Viracon project a clear, consistent and professional image. If you are an architect, simply ask for our Architectural Design team, otherwise please ask for a Customer Service Representative by dialing 1-800-533-2080. You will want to select the most appropriate options for your application before developing a glass specification. The Tunnel Test Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. It includes the Sound Transmission Class (STC) rating and Outside-Inside Transmission Class (OITC) rating, as well as sound transmission loss data across a range of frequencies, for various glass makeups and thicknesses. CALCULATOR 01. Contact us appearance. VTS’s superior seal integrity supported with a Special 12 Year Limited Warranty Laminated glass has proven to be an effective solution for blast mitigation. With our glass fabrication expertise, trusted supply chain integrity, and an unrivaled industry network, Viracon provides the platform to deliver state-of-the-art glass technology at scale. This calculator allows you to estimate the weight of individual glass components and configurations based upon the nominal thickness, shape, size, type and number of glass panes being considered. Save as PDF. A counterpoint is that birds do not perceive glass as an obstacle to their flight path. Viracon and its strategic partners envision a future of glass that creates more comfortable indoor environments, lowers energy costs, provides security that Note: The information in the Architectural Glass Specification is offered to assist in specifying Viracon’s Fabricated Glass Products. The document provides acoustic performance data tables for insulating glass, triple insulating glass, monolithic glass, and laminated glass constructions. To ensure this, Viracon has developed a corporate signature and guidelines for its use. Today, you can select from hundreds of sustainable architectural glass alternatives, as well as tap into design help and technical expertise, to meet LEED® credit requirements. Viracon has been producing heat strengthened glass with a surface compression between 4,000 and 7,000 psi (28 to 48 MPa) for more than 30 years and, within this time, has not experienced a single incidence of spontaneous breakage in heat strengthened glass. 800 Park Drive The terms and Laminated Glass Units Viracon's laminated glass units with a minimum . ©2019 VIRACON ALL RIGHTS RESERVED VMB-066 JUN2019 Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. In addition thicker glass provides improved sound control. Bird Friendly Glass. 3-7989 Glass Cleaning and Maintenance Recommendations Author: alissas Created Date: 5/18/2021 9:22:06 AM Viracon recommends viewing glass samples or full-size mockups to match vision and spandrel glass areas when the visible light transmission of the vision glass exceeds 14 percent. This corporate signature must be used in its entirety and reproduced from authorized original illustrations or EPS vector artwork. Nov 12, 2018 · The ability of glass to withstand a load is calculated utilizing ASTM E1300 Standard Practice for Determining Load Resistance of Glass in Buildings. Heat treated glass components fabricated by Viracon meet the requirements of ASTM C1048 May 6, 2020 · The raw glass or base material to which other materials or fabrication procedures are applied. All performance data is determined using LBL window 7. A minimum interlayer thickness of . For glass units with multiple glass plies, there could be 6 or more surfaces. ABOUT VIRACON Viracon, the nation’s leading single-source architectural glass fabricator, is based in Owatonna, Minnesota, and has facilities in Statesboro, Georgia; St. This document provides information to balance glass benefits with the adverse impact on birds. This means that all possible options for each different step of a project are May 6, 2020 · Glass formed on a bath of molten tin. Brian Savage is a product manager with Viracon. Thickness. May 6, 2020 · See Solar Reflective Coatings 800 Park Drive Owatonna, MN 55060 800. 030" pvb interlayer comply with ANSI Z97. This is referred to as an exterior offset. Refer to Viracon’s Glass Staining Tech Talk for additional information on glass staining and storage. Chemically Bonded to Glass and Secondary Sealant. Viracon Acoustical Glass is made from combinations of various glass types along with acoustical window frames to help you effectively reduce sound transmission from airplanes, trains, vehicles and other unwanted noises. Insulating units are designed to absorb stress on the unit caused by thermal expansion and pressure, provide a barrier to water and moisture infiltration, provide a gas-tight seal to prevent loss of any specialty gas fill and create a barrier the center of glass with no spacer system or framing. Viracon can help you with the calculations of these important values to ensure a safe and successful project. In some cases uncoated tinted glass products, such as Viracon's Involvement. *OITC is estimated based on this test. It is the user’s responsibility to the center of glass with no spacer system or framing. If you can’t find the rep you’re looking for contact us at (800) 533-2080 or glass@viracon. Upon our review of At Viracon, insulating glass units are sealed with a primary seal and a secondary seal of silicone. https://www. May 6, 2020 · The amount of heat gained through glass taking into consideration the effects U-value and shading coefficient. mammoths, our projects are unique, exciting, and . cultural, residential, commercial, and retail projects. Data is based on testing ~36" x 84" glass to ASTM E413-87 in an acoustical wall. Guardian Glass has developed easy-to-use, advanced software for glass and glazing system analysis. Save as PDF 800 Park Drive , Owatonna , MN 55060 US | (800) 533-2080 National Glass Association 344 Maple Ave West Unit 272 Vienna, VA 22180 703/442-4890. Viracon Thermal Spacer. Anadarko Tower/ Indianapolis Artsgarden/ Aurora Place/ Best Buy Corporate Headquarters/ 717 Texas (Calpine Center)/ Espirito Santo Plaza/ Federal Express Corporate the location where the glass area and water depth intersect. 1 or CPSC 16 CFR 1201 safety glazing standards. 2021 By Garibaldi Glass Guardian AG 43 - Guardian SNR 43 - Viracon VRE-38 - Vitro Solarban R100 Make-up Name Explore Viracon's innovative Glass Builder tool to find the perfect glass solution for your project. We’ve created files for our most popular, highest performing, glass products so you can easily compare multiple glass types in your model. We partner with best-in-class architecture firms and glazing contractors to provide great buildings with great glass that inspires and turns buildings into icons. In addition to the components needed to fabricate a glass type, there are a multiple enhancements available to further customize your glass selection. Viracon does not assume any responsibility for the adequacy of this specification for a particular application. May 6, 2020 · May 6, 2020, by Viracon The ratio is equal to the Visible Light Transmittance divided by the Solar Heat Gain Coefficient. George, Utah; and Nazaré Paulista, Brazil. 7 Quoted Freight Estimate: $1. In addition, Viracon’s laminated glass units comply with ASTM 1172 Standard Specification for Laminated Architectural Flat Glass. Most projects will document the glass used, appliations as well as project architects, glazing contractor, and contractor. These products require the base glass substrate, on which the coating is applied, to be either heat-strengthened or tempered. As a glass fabricator, Viracon has been actively involved in the ongoing bird friendly glass research, focusing specifically on finding practical solutions using conventional glass products for buildings with applied patterns. Winter and Summer U-Values are the only performance values available for spandrel glazing. Most Recent Quote Date: March-24 Viracon Index on that Date: 120. Energy Surcharge and Freight Notification. 800 Park Drive, Owatonna, MN 55060 US | (800) 533-2080 Our culture is the foundation of our success at Viracon. Figure 2 applies to fully tempered glass that is firmly supported on all four edges. com/projects/view/id/14/ May 6, 2020 · Glass with textured surface to transmit light but restrict vision. Laminated glass has proven to be an effective solution for blast mitigation. Viracon PLUS™ Smart Glass powered by HALIO® Trapezoid Shape Guide In addition to rectangle shapes, Viracon now offers insulated glazing units (IGUs) in trapezoid shapes. Viracon's solar and optical performance data is center of glass data based on the National Fenestration Rating Council measurement standards, calculated using Lawrence Berkeley National Laboratory's (LBNL) WINDOW 7 software. the center of glass with no spacer system or framing. August. Your Viracon Team.
zbymibq utfmq czo smxp dffn nnhfb svai jsuv tvubn yqwdp jnem qcpd icipt kixwr fxnkhe